{"title":"Safety Relays","description":"\u003ch2\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eSAFETY RELAYS\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable bgcolor=\"#fff\" style=\"width: 100%; height: 248.219px; background-color: rgb(255, 255, 255); border-collapse: collapse; border: 1px solid rgb(255, 255, 255);\" width=\"100%\"\u003e\n\u003ctbody bgcolor=\"#fff\" style=\"background-color: #fff;\"\u003e\n\u003ctr bgcolor=\"#fff\" style=\"height: 248.219px; background-color: rgb(255, 255, 255);\"\u003e\n\u003ctd bgcolor=\"#fff\" style=\"width: 66.0808%; height: 248.219px; background-color: rgb(255, 255, 255); border: 1px solid rgb(255, 255, 255);\"\u003e\n\u003cdiv bgcolor=\"#fff\" style=\"background-color: #fff;\" class=\"row\"\u003e\n\u003cdiv bgcolor=\"#fff\" style=\"background-color: #fff;\" class=\"col-lg-12\"\u003e\n\u003cp\u003e\u003cspan dir=\"auto\"\u003e\u003cspan\u003eAny time a relay is required and must be used in a \u003c\/span\u003e\u003cstrong\u003eSIF, it must conform and adhere to IEC 61508\u003c\/strong\u003e\u003cspan\u003e and to the relevant industry standards (i.e. IEC 61511).\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eTypical cases :\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003e- Controller cannot meet power requirement (V or A)\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e- Multiplication of contacts is required\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003e- Controller Safety Function must be inverted\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSIL certified relays\u003c\/strong\u003e\u003cspan\u003e are used in Oil \u0026amp; Gas or petrochemical industries and are also \u003c\/span\u003e\u003cstrong\u003ea must in many other industries \u003c\/strong\u003e\u003cspan\u003e(railways, automotive, power distribution), and any time a failure of the relay can cause a serious accident. \u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable bgcolor=\"#fff\" width=\"100%\" style=\"width: 100.536%; height: 1130px; background-color: rgb(255, 255, 255); border-collapse: collapse; border: 1px solid rgb(255, 255, 255);\"\u003e\n\u003ctbody bgcolor=\"#fff\" style=\"background-color: #fff;\"\u003e\n\u003ctr style=\"height: 359.234px;\"\u003e\n\u003ctd style=\"width: 66.3701%; background-color: rgb(255, 255, 255); border: 1px solid rgb(255, 255, 255); height: 359.234px;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eSTRENGTHS\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReduced foot print, high density, 12,5\/22,5 mm per ch.\u003c\/li\u003e\n\u003cli\u003eFull 3rd party certification, Coil-to-Contact SIL2\/3 TÜV certified\u003c\/li\u003e\n\u003cli\u003eTrue reliability, compatible to DO Card LM pulses\u003c\/li\u003e\n\u003cli\u003eReduced space\/eng. costs, smart line\/load monitoring with transparent fault indication\u003c\/li\u003e\n\u003cli\u003eLower cost of ownership\/maintenance, T-proof times: 10\/20 years\u003c\/li\u003e\n\u003cli\u003eReduced spare inventory, universal mounting: DIN-rail and Termination Boards\u003c\/li\u003e\n\u003cli\u003eHigher reliability in \u0026amp; outdoor, certified 40° to + 70° C\u003c\/li\u003e\n\u003cli\u003eTotally independent dual ch., dual circuits\u003c\/li\u003e\n\u003cli\u003eFull application coverage: modules available with 5 \u0026amp; 10 Amps contact, NE\/ND application\u003c\/li\u003e\n\u003cli\u003eHarsh environment resistance, G3 conformal coating\u003c\/li\u003e\n\u003cli\u003eReliable switching operations, gold-plated relay contacts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible to any Line Monitored DO card\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 33.6299%; background-color: rgb(255, 255, 255); border: 1px solid rgb(255, 255, 255); height: 359.234px;\"\u003e\n\u003ch3\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/POWER_SUPPLIERS_web2.png?v=1764792376\"\u003e\u003c\/h3\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#fff\" style=\"background-color: rgb(255, 255, 255); height: 309.688px;\"\u003e\n\u003ctd bgcolor=\"#fff\" style=\"width: 66.3701%; background-color: rgb(255, 255, 255); border: 1px solid rgb(255, 255, 255); height: 309.688px;\"\u003e\n\u003ch3\u003e\n\u003cspan style=\"color: rgb(0, 170, 255);\"\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eENCLOSURE CHARACTERISTICS\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh channel density resulting from innovative circuit design using advanced surface mount components\u003c\/li\u003e\n\u003cli\u003eSingle or dual channel models\u003c\/li\u003e\n\u003cli\u003ePlug-in screw terminal blocks to secure wires up to 2.5 mm2\u003c\/li\u003e\n\u003cli\u003eConfiguration components are easily accessed by removing the side cover or via connector front panel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd bgcolor=\"#fff\" style=\"width: 33.6299%; background-color: rgb(255, 255, 255); border: 1px solid rgb(255, 255, 255); height: 309.688px;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eSTRUCTURE\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/safety-relays_caratteristiche.png?v=1770998620\"\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#fff\" style=\"background-color: rgb(255, 255, 255); height: 461.078px;\"\u003e\n\u003ctd bgcolor=\"#fff\" style=\"width: 66.3701%; background-color: rgb(255, 255, 255); border: 1px solid rgb(255, 255, 255); height: 461.078px;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eLINE \u0026amp; LOAD MONITORING\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSIL certified relays\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare used for critical loops where careful consideration should be given to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLine and Load Monitoring\u003c\/strong\u003e. In a de-energize to safety application a wire\/coil failure leads to a safety status.\u003cbr\u003eIn an energize to safety application line failures leads to a dangerous status. In both cases\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efailure detection is important\u003c\/strong\u003e, if not essential.\u003c\/p\u003e\n\u003cp\u003eOther diagnostics applications are monitoring the load status to prevent spurious trips or to verify the condition of the individual coil in a redundant coil SOV. In\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF\u0026amp;G system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eline\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediagnostics is a must\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand regulated by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFPA 72 code\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eControl system diagnostic capabilities are designed to work when no device is interposed between the control system and the load. If a relay is placed in the loop,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethe diagnostic function stops at the relay input circuit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(coil). To perform line monitoring from field device to controller, a SIL relay with built-in diagnostic circuit is required.\u003cbr\u003eGM International relays\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewill perform diagnostics\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof the load, wire, power supply and internal coils\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ein all operating conditions\u003c\/strong\u003e, providing an independent alarm contact as well as transparently transferring the fault indication to compatible DO cards.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd bgcolor=\"#fff\" style=\"width: 33.6299%; background-color: rgb(255, 255, 255); border: 1px solid rgb(255, 255, 255); height: 461.078px;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eOUR PATENTED DIAGNOSTICS FEATURES\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWorks in all load conditions: On\/Off\u003c\/li\u003e\n\u003cli\u003eOperates with OPEN\/CLOSE relay\u003c\/li\u003e\n\u003cli\u003eSome units are software configurable\u003c\/li\u003e\n\u003cli\u003eSuitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNE\/ND\u003c\/strong\u003e, AC\/DC loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransparent\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efault indication to compatible system\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMonitors:\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e- Load supply voltage\u003cbr\u003e- Load current\u003cbr\u003e- Load resistance\u003cbr\u003e- Earth leakage\u003cbr\u003e- Internal relay coils\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","products":[{"product_id":"d1092d","title":"D1092D","description":"\u003cp\u003eSIL 3 Relay Output Module DIN-Rail Model D1092D\u003c\/p\u003e\n\n\u003cp\u003eThe dual channel DIN Rail Relay Output, D1092D, is relay modules suitable for the switching of safety related circuits, up to SIL 3 level according to IEC61508:2010 Ed. 2, for high risk industries. It provides isolation between input and output contacts. D1092D provides 2 SPST contact for normally energized loads and 2 SPST contact for normally de-energized loads. When the relay is energized, the contacts are closed. When the relay is de-energized, the contacts are open. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-to-system signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL3\/SC3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2, Division 2\u003c\/li\u003e\n\u003cli\u003e2 fully independent channels.\u003c\/li\u003e\n\u003cli\u003e1 SPST contact for NE load and 1 SPST contact for ND load for each channel.\u003c\/li\u003e\n\u003cli\u003e5 A inrush current at 30 Vdc \/ 250 Vac.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0240\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0091\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1092D\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927544672638,"sku":null,"price":221.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0616_R00_4ac7d3fd-a7a3-472e-b973-811f069bb6f6.jpg?v=1771101878"},{"product_id":"d1092d-069","title":"D1092D-069","description":"\u003cp\u003eSIL 3 Relay Output Module DIN-Rail\u003cbr\u003e\n Model D1092D-069\u003c\/p\u003e\n\n\u003cp\u003eThe single and dual channel DIN Rail Relay Output, D1092S-069 and D1092D-069 are relay modules suitable for the switching of safety related circuits, up to SIL 3 level according to IEC61508:2010 Ed. 2, for high risk industries. Isolation is provided between input and output contacts, and between the two channels of D1092D-069. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-tosystem signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL3\/SC3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2, Division 2\u003c\/li\u003e\n\u003cli\u003e2 fully independent channels.\u003c\/li\u003e\n\u003cli\u003e1 SPST NO contact and 1 SPST NC contact for each channel.\u003c\/li\u003e\n\u003cli\u003e5 A inrush current at 30 Vdc \/ 250 Vac.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0248\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0101\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1092D-069\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927544869246,"sku":null,"price":238.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1167_R00_c2f952dd-87ce-4aea-a445-46f7e4193763.jpg?v=1771101886"},{"product_id":"d1092s","title":"D1092S","description":"\u003cp\u003eSIL 3 Relay Output Module DIN-Rail Model D1092S\u003c\/p\u003e\n\n\u003cp\u003eThe single channel DIN Rail Relay Output, D1092S, is relay module suitable for the switching of safety related circuits, up to SIL 3 level according to IEC61508:2010 Ed. 2, for high risk industries. It provides isolation between input and output contacts. D1092S provides 1 SPST contact for normally energized loads and 1 SPST contact for normally de-energized loads. When the relay is energized, the contacts are closed. When the relay is de-energized, the contacts are open. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-to-system signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL3\/SC3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2, Division 2\u003c\/li\u003e\n\u003cli\u003e1 SPST contact for NE load and 1 SPST contact for ND load for each channel.\u003c\/li\u003e\n\u003cli\u003e5 A inrush current at 30 Vdc \/ 250 Vac.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0240\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0091\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1092S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927545164158,"sku":null,"price":141.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0745_R00_f02a5b0d-de40-42ce-be6a-e618d479500d.jpg?v=1771101894"},{"product_id":"d1092s-069","title":"D1092S-069","description":"\u003cp\u003eSIL 3 Relay Output Module DIN-Rail\u003cbr\u003e\n Model D1092S-069\u003c\/p\u003e\n\n\u003cp\u003eThe single and dual channel DIN Rail Relay Output, D1092S-069 and D1092D-069 are relay modules suitable for the switching of safety related circuits, up to SIL 3 level according to IEC61508:2010 Ed. 2, for high risk industries. Isolation is provided between input and output contacts, and between the two channels of D1092D-069. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-tosystem signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL3\/SC3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2, Division 2\u003c\/li\u003e\n\u003cli\u003e1 SPST NO contact and 1 SPST NC contact for each channel.\u003c\/li\u003e\n\u003cli\u003e5 A inrush current at 30 Vdc \/ 250 Vac.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0248\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0101\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1092S-069\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927545885054,"sku":null,"price":156.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1168_R00_7382b3dc-eca6-478f-879c-a3e17b91e31d.jpg?v=1771101901"},{"product_id":"d1093s","title":"D1093S","description":"\u003cp\u003eSIL 3 Relay Output Module with\u003cbr\u003e\nLine and Load diagnostics DIN-Rail\u003cbr\u003e\nModel D1093S\u003c\/p\u003e\n\n\u003cp\u003eThe single channel DIN Rail Relay Output D1093S is a relay module suitable for the switching of safety related circuits, up to SIL 3 level according to IEC61508:2010 Ed. 2, for high risk industries. It provides isolation between the input and output contact. D1093S provides 1 DPST contact for normally energized loads and 1 SPST contact for normally de-energized loads. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-tosystem signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL2\/SC3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2, Division 2.\u003c\/li\u003e\n\u003cli\u003eLine and Load open diagnostic in NE and ND conditions.\u003c\/li\u003e\n\u003cli\u003eDPST contact for NE load and 1 SPST contact for ND load.\u003c\/li\u003e\n\u003cli\u003e5 A inrush current at 30 Vdc \/ 250 Vac.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0242\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0093\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D1093S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927545983358,"sku":null,"price":348.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0617_R00_07e3897e-50c4-44ef-9031-1517b6ed02cd.jpg?v=1771101908"},{"product_id":"d5090s","title":"D5090S","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A NE Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5090 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available two NO contacts for Normally Energized (NE) loads, in order to disconnect the load on both supply lines, and a NC contact for service purpose. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE loads with NE driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0330\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0109\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5090S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.D5090S\/id-2491335\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927558664574,"sku":null,"price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0363_R01_70ba834f-6c83-4f1b-b74d-8044add03891.png?v=1771102380"},{"product_id":"d5090s-086","title":"D5090S-086","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A NE Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5090-086 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available two NC contacts for Normally Energized (NE) loads, in order to disconnect the load on both supply lines, and a NO contact for service purpose. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE loads with ND driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0431\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0267\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5090S-086\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.D5090S-086\/id-2488218\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927558861182,"sku":null,"price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0360_R00_c155a5ae-ab6b-4250-9bf2-b092fd16630c.jpg?v=1771102388"},{"product_id":"d5090s-102","title":"D5090S-102","description":"\u003cp\u003eSIL3 Relay Out Low-Power Module for 5 A NE Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5090-102 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available two NO contacts for Normally Energized (NE) loads, in order to disconnect the load on both supply lines, and a NC contact for service purpose. This model is specifically designed to reach high functional safety at minimum power consumption and low input voltage. Compatibility with specific DO cards with pulse testing needs to be verified.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE loads with NE driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eLow current consumption\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0857\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0456\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5090S-102\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.D5090S-102\/id-2491310\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927559418238,"sku":null,"price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0639_R01_cb2b8923-4885-4d06-a54b-56ea14464ff8.png?v=1771102396"},{"product_id":"d5091s","title":"D5091S","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A ND Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5091 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available a NO and a NC contact for Normally De-energized (ND) loads, with either Normally De-energized or Normally Energized coil, and a contact for service purpose. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for ND\/F\u0026amp;G loads with ND\/NE driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0327\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0110\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5091S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.D5091S\/id-2488224\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927559614846,"sku":null,"price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0364_R00_658f762c-ddaf-4f0a-94fa-e6b306cee62e.jpg?v=1771102403"},{"product_id":"d5091s-103","title":"D5091S-103","description":"\u003cp\u003eSIL3 Relay Out Low-Power Module for 5 A ND Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5091-103 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available a NO and a NC contact for Normally De-energized (ND) loads, with either Normally De-energized or Normally Energized coil, and a contact for service purpose. This model is specifically designed to reach high functional safety at minimum power consumption and low input voltage. Compatibility with specific DO cards with pulse testing needs to be verified.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for ND\/F\u0026amp;G loads with ND\/NE driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLow current consumption\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0858\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0457\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5091S-103\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.D5091S-103\/id-2491503\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927559942526,"sku":null,"price":154.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0640_R01_b8075e8e-9dec-4859-9bd5-050ed6da735b.png?v=1771102412"},{"product_id":"d5093d","title":"D5093D","description":"\u003cp\u003eSIL3 24\/220Vdc\/Vac Transistor-Out Detector\u003c\/p\u003e\n\n\u003cp\u003eThe 24\/220Vdc\/Vac Transistor-Out Detector D5093 module is a unit suitable for applications requiring SIL 3 level in safety related systems for high risk industries. Each channel is able to reflect the presence of a 24 to 220 Vac\/Vdc input signal to the output by closing an optically coupled NO open-drain transistor (solid-state relay, MOSFET output). The presence of the 24 to 220 Vac\/Vdc input signal is also indicated by a yellow LED on the front panel. The input switching voltage levels are selected, according to the applied input signal, by means of an internal dip-switch (overload protected).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003e2 fully independent channels\u003c\/li\u003e\n\u003cli\u003eTwo port isolation, Input\/Output\u003c\/li\u003e\n\u003cli\u003eHigh Density, two channels per unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0420\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0175\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5093D\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927560368510,"sku":null,"price":211.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0359_R00_275072a6-e136-40e0-8c4e-d2ed9a9ed852.jpg?v=1771102419"},{"product_id":"d5093d-tb","title":"D5093D-TB","description":"\u003cp\u003eSIL3 24\/220Vdc\/Vac Transistor-Out Detector\u003c\/p\u003e\n\n\u003cp\u003eThe 24\/220Vdc\/Vac Transistor-Out Detector D5093-TB module is a unit suitable for applications requiring SIL 3 level in safety related systems for high risk industries. Each channel is able to reflect the presence of a 24 to 220 Vac\/Vdc input signal to the output by closing an optically coupled NO open-drain transistor (solid-state relay, MOSFET output). The presence of the 24 to 220 Vac\/Vdc input signal is also indicated by a yellow LED on the front panel. The input switching voltage levels are selected, according to the applied input signal, by means of an internal dip-switch (overload protected).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003e2 fully independent channels\u003c\/li\u003e\n\u003cli\u003eTwo port isolation, Input\/Output\u003c\/li\u003e\n\u003cli\u003eHigh Density, two channels per unit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS1497\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0541\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5093D-TB\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927561023870,"sku":null,"price":203.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1128_R00_7775b9ca-b3ca-4eb6-a503-476fe599e84f.png?v=1771102426"},{"product_id":"d5093s","title":"D5093S","description":"\u003cp\u003eSIL3 24\/220Vdc\/Vac Transistor-Out Detector\u003c\/p\u003e\n\n\u003cp\u003eThe 24\/220Vdc\/Vac Transistor-Out Detector D5093 module is a unit suitable for applications requiring SIL 3 level in safety related systems for high risk industries. Each channel is able to reflect the presence of a 24 to 220 Vac\/Vdc input signal to the output by closing an optically coupled NO open-drain transistor (solid-state relay, MOSFET output). The presence of the 24 to 220 Vac\/Vdc input signal is also indicated by a yellow LED on the front panel. The input switching voltage levels are selected, according to the applied input signal, by means of an internal dip-switch (overload protected).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003eTwo port isolation, Input\/Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0420\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0175\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5093S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927561351550,"sku":null,"price":132.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0358_R00_b6159a64-f239-47ef-809f-41cdf1c8a33d.jpg?v=1771102432"},{"product_id":"d5093s-tb","title":"D5093S-TB","description":"\u003cp\u003eSIL3 24\/220Vdc\/Vac Transistor-Out Detector\u003c\/p\u003e\n\n\u003cp\u003eThe 24\/220Vdc\/Vac Transistor-Out Detector D5093-TB module is a unit suitable for applications requiring SIL 3 level in safety related systems for high risk industries. Each channel is able to reflect the presence of a 24 to 220 Vac\/Vdc input signal to the output by closing an optically coupled NO open-drain transistor (solid-state relay, MOSFET output). The presence of the 24 to 220 Vac\/Vdc input signal is also indicated by a yellow LED on the front panel. The input switching voltage levels are selected, according to the applied input signal, by means of an internal dip-switch (overload protected).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003eTwo port isolation, Input\/Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS1497\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0541\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5093S-TB\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927561679230,"sku":null,"price":128.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1129_R00_14b7b854-ed09-47ad-a7d4-38bed5d9d5d0.png?v=1771102439"},{"product_id":"d5094s","title":"D5094S","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A NE\/ND Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5094 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available 2+2 NO relay contacts connected in parallel and then in series to avoid spurious trip and to increase process availability. High process availability SIL 3 Safety Function for both Normally Energized (NE) and Normally De-energized (ND) \/ F\u0026amp;G loads is available. Load can be isolated from supply on both polarities. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eHigh process availability to avoid spurious trips\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0538\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0299\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5094S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.D5094S\/id-2488226\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927562039678,"sku":null,"price":188.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0641_R01.png?v=1771102447"},{"product_id":"d5094s-104","title":"D5094S-104","description":"\u003cp\u003eSIL3 Relay Low-Volt Module for 5 A NE\/ND Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5094-104 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available 2+2 NO relay contacts connected in parallel and then in series to avoid spurious trip and to increase process availability. High process availability SIL 3 Safety Function for both Normally Energized (NE) and Normally De-energized (ND) \/ F\u0026amp;G loads is available. Load can be isolated from supply on both polarities. This model is specifically designed to reach high functional safety at input voltage.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eHigh process availability to avoid spurious trips\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0871\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0460\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5094S-104\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.D5094S-104\/id-2491401\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927562596734,"sku":null,"price":188.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0641_R01_6bdb71cd-c10c-4e01-bb23-596fe326a511.png?v=1771102455"},{"product_id":"d5095s","title":"D5095S","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A NE\/ND Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5095 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available 2+2 NC relay contacts connected in parallel and then in series to avoid spurious trip and to increase process availability. High process availability SIL 3 Safety Function for both Normally Energized (NE) and Normally De-energized (ND) \/ F\u0026amp;G loads is available. Load can be isolated from supply on both polarities. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eHigh process availability to avoid spurious trips\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0636\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0300\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5095S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927563219326,"sku":null,"price":188.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0362_R00_2beb73e3-6d06-46a2-a4e5-531d046b496c.jpg?v=1771102463"},{"product_id":"d5095s-105","title":"D5095S-105","description":"\u003cp\u003eSIL3 Relay Low-Volt Module for 5 A NE\/ND Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5095-105 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available 2+2 NC relay contacts connected in parallel and then in series to avoid spurious trip and to increase process availability. High process availability SIL 3 Safety Function for both Normally Energized (NE) and Normally De-energized (ND) \/ F\u0026amp;G loads is available. Load can be isolated from supply on both polarities. This model is specifically designed to reach high functional safety at input voltage.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLow input voltage\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eHigh process availability to avoid spurious trips\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0872\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0461\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5095S-105\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927563481470,"sku":null,"price":188.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0642_R01_a2e94b4d-deb7-467c-8042-0f7e54514cc5.png?v=1771102471"},{"product_id":"d5096s","title":"D5096S","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A NE\/ND Loads with LFD\u003c\/p\u003e\n\n\u003cp\u003eThe D5096 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available 2+2 NO relay contacts connected in parallel and then in series to avoid spurious trip and to increase process availability. High process availability SIL 3 Safety Function for both Normally Energized (NE) and Normally De-energized (ND) \/ F\u0026amp;G loads is available. Load can be isolated from supply on both polarities. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering. Line and load short\/open circuit detection and load voltage monitoring are provided, both when the load is off and when the load is on. The fault in the field is directly mirrored to the PLC DO and it is also reported by opening the fault output.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eHigh process availability to avoid spurious trips\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Load short\/open circuit detection\u003c\/li\u003e\n\u003cli\u003eLoad voltage monitoring\u003c\/li\u003e\n\u003cli\u003eField fault mirroring to the PLC DO\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output\/Supply isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0638\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0301\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5096S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.D5096S\/id-2488254\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927563841918,"sku":null,"price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0365_R00_bd30af8c-e1fe-4439-8c90-bea1fe2973a8.jpg?v=1771102479"},{"product_id":"d5096s-100","title":"D5096S-100","description":"\u003cp\u003eSIL3\/2 5 A Relay with LFD \u0026amp; Universal Fault Mirror\u003c\/p\u003e\n\n\u003cp\u003eThe D5096-100 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available 2+2 NO relay contacts connected in parallel and then in series to avoid spurious trip and to increase process availability. High process availability SIL 3 Safety Function for Normally Energized (NE) and SIL 2 for Normally De-energized (ND) \/ F\u0026amp;G loads is available. Load can be isolated from supply on both polarities. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering. Line and load short\/open circuit detection and load voltage monitoring are provided, both when the load is off and when the load is on. The fault in the field is directly mirrored to the PLC DO by opening the input and it is also reported by opening the fault output. The fault mirroring technique guarantees a wide compatibility to PLC DO cards.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE loads with NE driver\u003c\/li\u003e\n\u003cli\u003eSIL 2 \/ SC 3 for ND loads with ND driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eHigh process availability to avoid spurious trips\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Load short\/open circuit detection\u003c\/li\u003e\n\u003cli\u003eLoad voltage monitoring\u003c\/li\u003e\n\u003cli\u003eUniversal field fault mirroring to the PLC DO\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output\/Supply isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0842\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0439\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5096S-100\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.D5096S-100\/id-2488571\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927564464510,"sku":null,"price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0372_R00_7f4e3db9-966f-4e0f-ab12-71b436123f02.jpg?v=1771102486"},{"product_id":"d5096s-106","title":"D5096S-106","description":"\u003cp\u003eSIL3 Relay Low-V Module for 5 A NE\/ND Loads with LFD\u003c\/p\u003e\n\n\u003cp\u003eThe D5096-106 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available 2+2 NO relay contacts connected in parallel and then in series to avoid spurious trip and to increase process availability. High process availability SIL 3 Safety Function for both Normally Energized (NE) and Normally De-energized (ND) \/ F\u0026amp;G loads is available. Load can be isolated from supply on both polarities. This model is specifically designed to reach high functional safety at input voltage. Line and load short\/open circuit detection and load voltage monitoring are provided, both when the load is off and when the load is on. The fault in the field is directly mirrored to the PLC DO and it is also reported by opening the fault output.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLow input voltage\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eHigh process availability to avoid spurious trips\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Load short\/open circuit detection\u003c\/li\u003e\n\u003cli\u003eLoad voltage monitoring\u003c\/li\u003e\n\u003cli\u003eField fault mirroring to the PLC DO\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output\/Supply isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0873\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0462\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5096S-106\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.D5096S-106\/id-2491623\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927564857726,"sku":null,"price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0643_R01_e062bb99-b817-4fe4-921b-037efff8463f.png?v=1771102494"},{"product_id":"d5097s","title":"D5097S","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A NE\/ND Loads with LFD\u003c\/p\u003e\n\n\u003cp\u003eThe D5097 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available 2+2 NC relay contacts connected in parallel and then in series to avoid spurious trip and to increase process availability. High process availability SIL 3 Safety Function for both Normally Energized (NE) and Normally De-energized (ND) \/ F\u0026amp;G loads is available. Load can be isolated from supply on both polarities. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering. Line and load short\/open circuit detection and load voltage monitoring are provided, both when the load is off and when the load is on. The fault in the field is directly mirrored to the PLC DO and it is also reported by opening the fault output.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eHigh process availability to avoid spurious trips\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Load short\/open circuit detection\u003c\/li\u003e\n\u003cli\u003eLoad voltage monitoring\u003c\/li\u003e\n\u003cli\u003eField fault mirroring to the PLC DO\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output\/Supply isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0639\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0302\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5097S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927565382014,"sku":null,"price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0366_R00_07c868f8-38a3-4a3a-a7ec-0ee50eb63f16.jpg?v=1771102502"},{"product_id":"d5097s-107","title":"D5097S-107","description":"\u003cp\u003eSIL3 Relay Low-V Module for 5 A NE\/ND Loads with LFD\u003c\/p\u003e\n\n\u003cp\u003eThe D5097-107 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available 2+2 NC relay contacts connected in parallel and then in series to avoid spurious trip and to increase process availability. High process availability SIL 3 Safety Function for both Normally Energized (NE) and Normally De-energized (ND) \/ F\u0026amp;G loads is available. Load can be isolated from supply on both polarities. This model is specifically designed to reach high functional safety at input voltage. Line and load short\/open circuit detection and load voltage monitoring are provided, both when the load is off and when the load is on. The fault in the field is directly mirrored to the PLC DO and it is also reported by opening the fault output.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLow input voltage\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eHigh process availability to avoid spurious trips\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Load short\/open circuit detection\u003c\/li\u003e\n\u003cli\u003eLoad voltage monitoring\u003c\/li\u003e\n\u003cli\u003eField fault mirroring to the PLC DO\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output\/Supply isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0874\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0463\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5097S-107\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927565709694,"sku":null,"price":359.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0644_R01_c71161ff-d1e4-4543-b1df-e774bcf41556.png?v=1771102510"},{"product_id":"d5098d","title":"D5098D","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A NE Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5098 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available NO contacts for up to two Normally Energized (NE) loads and NC contacts for service purpose. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE loads with NE driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0675\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0305\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5098D\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.D5098D\/id-2488572\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927565775230,"sku":null,"price":223.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0369_R00_e377cb11-d938-4a77-b38d-49b09f778e86.jpg?v=1771102517"},{"product_id":"d5098s","title":"D5098S","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A NE Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5098 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available NO contacts for up to two Normally Energized (NE) loads and NC contacts for service purpose. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE loads with NE driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0675\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0305\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5098S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.D5098S\/id-2488723\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927565971838,"sku":null,"price":141.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0368_R00_e3a64610-27d3-464c-9fbc-c124fbd01302.jpg?v=1771102525"},{"product_id":"d5099d-108","title":"D5099D-108","description":"\u003cp\u003eRelay Out Module for 5 A Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5099-108 is a relay module, which makes available up to two SPDT (Single Pole Double Throw) contacts isolated from the input. Compatibility with specific DO cards with pulse testing needs to be verified.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eBoth NO and NC contact available\u003c\/li\u003e\n\u003cli\u003eLow activation coil current (\u0026amp;lt; 10 mA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0875\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0538\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5099D-108\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927566102910,"sku":null,"price":158.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0645_R01_59262b55-6685-4579-8e23-1dbb975b5155.png?v=1771102534"},{"product_id":"d5099s","title":"D5099S","description":"\u003cp\u003eRelay Out Module for 5 A Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5099 is a relay module, which makes available a SPDT (Single Pole Double Throw) contact isolated from the input. Compatibility with specific DO cards with pulse testing needs to be verified.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eBoth NO and NC contact available\u003c\/li\u003e\n\u003cli\u003eLow activation coil current (\u0026amp;lt; 10 mA)\u003c\/li\u003e\n\u003cli\u003eInput\/Output isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0823\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0394\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5099S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927566233982,"sku":null,"price":99.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0927_R01_85303199-b4fa-4e08-a0d5-3a6f8c7e469f.png?v=1771102542"},{"product_id":"d5099s-108","title":"D5099S-108","description":"\u003cp\u003eRelay Out Module for 5 A Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5099-108 is a relay module, which makes available up to two SPDT (Single Pole Double Throw) contacts isolated from the input. Compatibility with specific DO cards with pulse testing needs to be verified.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eBoth NO and NC contact available\u003c\/li\u003e\n\u003cli\u003eLow activation coil current (\u0026amp;lt; 10 mA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0875\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0538\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5099S-108\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927566332286,"sku":null,"price":105.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0646_R01_6cd74d5a-ae7f-4944-bbf0-c2ab535b2943.png?v=1771102550"},{"product_id":"d5290s","title":"D5290S","description":"\u003cp\u003eSIL3 Relay Out Module for 10 A NE Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5290 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available two NO contacts for Normally Energized (NE) loads, in order to disconnect the load on both supply lines, and a NC contact for service purpose. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering. This relay module is not suitable for low-current consumption applications (system-to-system signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE loads with NE driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003eUp to 10 A functional \/ 16 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0336\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0111\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927569084798,"sku":null,"price":160.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0381_R00_f8ab26fd-125f-47d3-9ca7-19b63cacaccb.jpg?v=1771102663"},{"product_id":"d5290s-078","title":"D5290S-078","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A NE\/ND Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5290-078 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available up to four NO contacts and two NC contacts, which can be externally connected for multiple Normally Energized (NE) or Normally De-energized (ND) loads, with single or both supply lines disconnection, and additional service loads. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering. This relay module is not suitable for low-current consumption applications (system-to-system signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 8 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eMultiple contacts (up to 4 NE or 2 ND loads)\u003c\/li\u003e\n\u003cli\u003eInput\/Output isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0366\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0152\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-078\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927569117566,"sku":null,"price":180.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0382_R00_cf08c792-493c-493e-a4c0-8e1fcbe04632.jpg?v=1771102671"},{"product_id":"d5290s-078sa","title":"D5290S-078\/SA","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A NE\/ND Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5290-078\/SA is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available up to four NO contacts and two NC contacts, which can be externally connected for multiple Normally Energized (NE) or Normally De-energized (ND) loads, with single or both supply lines disconnection, and additional service loads. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-to-system signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with NE driver\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 8 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eMultiple contacts (up to 3 NE loads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0457\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0173\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-078\/SA\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927569150334,"sku":null,"price":139.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0383_R00_53a0cef7-62ee-46a2-99d8-0a66d15e1d1f.jpg?v=1771102678"},{"product_id":"d5290s-079","title":"D5290S-079","description":"\u003cp\u003eSIL3 115 Vac Relay Out Module for 5 A NE\/ND Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5290-079 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available up to four NO contacts and two NC contacts, which can be externally connected for multiple Normally Energized (NE) or Normally De-energized (ND) loads, with single or both supply lines disconnection, and additional service loads. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-to-system signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with NE driver\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 8 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eMultiple contacts (up to 4 NE or 2 ND loads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0367\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0153\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-079\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927569248638,"sku":null,"price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0384_R00_f8e2318f-c324-4395-9761-c9276e7d719d.jpg?v=1771102685"},{"product_id":"d5290s-080","title":"D5290S-080","description":"\u003cp\u003eSIL3 115 Vac Relay Out Module for 10 A NE Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5290-080 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available two NO contacts for Normally Energized (NE) loads, in order to disconnect the load on both supply lines, and a NC contact for service purpose. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-to-system signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE loads with NE driver\u003c\/li\u003e\n\u003cli\u003eUp to 10 A functional \/ 16 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0375\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0151\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-080\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927569445246,"sku":null,"price":145.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0385_R00_28a39d6c-44ea-4ff0-b8bc-f04afda49e91.jpg?v=1771102692"},{"product_id":"d5290s-084","title":"D5290S-084","description":"\u003cp\u003eSIL3 110 Vdc Relay Out Module for 5 A NE\/ND Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5290-084 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available up to four NO contacts and two NC contacts, which can be externally connected for multiple Normally Energized (NE) or Normally De-energized (ND) loads, with single or both supply lines disconnection, and additional service loads. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-to-system signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with NE driver\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 8 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eMultiple contacts (up to 4 NE or 2 ND loads)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0415\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0170\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-084\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927570002302,"sku":null,"price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0386_R00_40ae02d0-474e-4f65-a195-0e9313195d39.jpg?v=1771102700"},{"product_id":"d5290s-091","title":"D5290S-091","description":"\u003cp\u003eSIL3 230 Vac Relay Out Module for 10 A NE Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5290-091 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available two NO contacts for Normally Energized (NE) loads, in order to disconnect the load on both supply lines, and a NC contact for service purpose. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-to-system signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE loads with NE driver\u003c\/li\u003e\n\u003cli\u003eUp to 10 A functional \/ 16 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0637\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0294\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-091\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927570100606,"sku":null,"price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0391_R00_36a87d27-2d03-4134-bbbd-61c27327512f.jpg?v=1771102708"},{"product_id":"d5290s-092","title":"D5290S-092","description":"\u003cp\u003eSIL3 48 Vdc Relay Out Module for 10 A NE Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5290-092 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available two NO contacts for Normally Energized (NE) loads, in order to disconnect the load on both supply lines, and a NC contact for service purpose. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-to-system signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE loads with NE driver\u003c\/li\u003e\n\u003cli\u003eUp to 10 A functional \/ 16 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0372\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S-092\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927570592126,"sku":null,"price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0928_R01_e5166ab2-0db6-41b4-999b-364d8ffdfb4f.png?v=1771102716"},{"product_id":"d5290ssa","title":"D5290S\/SA","description":"\u003cp\u003eSIL3 Relay Out Module for 10 A NE Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5290\/SA is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available two NO contacts for Normally Energized (NE) loads, in order to disconnect the load on both supply lines, and a NC contact for service purpose. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-to-system signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE loads with NE driver\u003c\/li\u003e\n\u003cli\u003eUp to 10 A functional \/ 16 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0376\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0150\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5290S\/SA\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927571083646,"sku":null,"price":117.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0395_R00_4d979121-6b63-4b57-8e57-63362bc37720.jpg?v=1771102724"},{"product_id":"d5291s","title":"D5291S","description":"\u003cp\u003eSIL3 Relay Out Module for 10 A ND Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5291 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available a NO and a NC contact for Normally De-energized (ND) loads, with either Normally De-energized or Normally Energized coil, and a contact for service purpose. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering. This relay module is not suitable for low-current consumption applications (system-to-system signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for ND loads with ND\/NE driver\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003eUp to 10 A functional \/ 16 A inrush current\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0337\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0112\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5291S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927571313022,"sku":null,"price":160.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0396_R00_40a17c97-20f0-4a88-8d0c-b6772ae1a96b.jpg?v=1771102731"},{"product_id":"d5291s-097","title":"D5291S-097","description":"\u003cp\u003eSIL3 48 Vdc Relay Out Module for 10 A ND Loads\u003c\/p\u003e\n\n\u003cp\u003eThe D5291-097 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available a NO and a NC contact for Normally De-energized (ND) loads, with Normally Energized coil, and a contact for service purpose. Compatibility with specific DO cards with pulse testing needs to be verified. This relay module is not suitable for low-current consumption applications (system-to-system signalling, driving LEDs, etc.).\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for ND loads with NE driver\u003c\/li\u003e\n\u003cli\u003eUp to 10 A functional \/ 16 A inrush current\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0757\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0367\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5291S-097\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927571444094,"sku":null,"price":192.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0868_R01_26a30c04-e4ef-4c7d-a633-0f826f6f8b70.png?v=1771102740"},{"product_id":"d5293s","title":"D5293S","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A NE Loads with LFD\u003c\/p\u003e\n\n\u003cp\u003eThe D5293 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available two NO contacts for Normally Energized (NE) loads, in order to disconnect the load on both supply lines, and a NC contact for service purpose. Load can be isolated from supply on both polarities. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering. Line and load short\/open circuit detection and load voltage monitoring are provided, both when the load is off and when the load is on. The fault in the field is directly mirrored to the PLC DO and it is also reported by opening the fault output. Diagnostic parameters are programmable and can also be monitored\/configured through Modbus.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE loads with NE driver\u003c\/li\u003e\n\u003cli\u003eSIL 2 \/ SC 3 for FAULT OUTPUTS\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Load short\/open circuit detection\u003c\/li\u003e\n\u003cli\u003eLoad voltage monitoring\u003c\/li\u003e\n\u003cli\u003eField fault mirroring to the PLC DO\u003c\/li\u003e\n\u003cli\u003eModbus RTU RS-485 for monitor \u0026amp; configuration\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output\/Supply isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0339\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0122\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5293S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927571640702,"sku":null,"price":477.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0390_R00_bd7bab65-2b4e-4f7b-94af-39bc18aa1ef6.jpg?v=1771102748"},{"product_id":"d5294s","title":"D5294S","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A NE\/ND Loads with LFD\u003c\/p\u003e\n\n\u003cp\u003eThe D5294 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available 2+2 NO relay contacts connected in parallel and then in series to avoid spurious trip and to increase process availability. High process availability SIL 3 Safety Function for both Normally Energized (NE) and Normally De-energized (ND) \/ F\u0026amp;G loads is available. Load can be isolated from supply on both polarities. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering. Line and load short\/open circuit detection and load voltage monitoring are provided, both when the load is off and when the load is on. The fault in the field is directly mirrored to the PLC DO and it is also reported by opening the fault output. Diagnostic parameters are programmable and can also be monitored\/configured through Modbus.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with NE\/ND driver\u003c\/li\u003e\n\u003cli\u003eSIL 2 \/ SC 3 for FAULT OUTPUTS\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\/Div. 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eHigh process availability to avoid spurious trips\u003c\/li\u003e\n\u003cli\u003eModbus RTU RS-485 for monitor \u0026amp; configuration\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output\/Supply isolation\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eLine and Load short\/open circuit detection\u003c\/li\u003e\n\u003cli\u003eLoad voltage monitoring\u003c\/li\u003e\n\u003cli\u003eEarth leakage monitoring\u003c\/li\u003e\n\u003cli\u003eInternal coil integrity monitoring\u003c\/li\u003e\n\u003cli\u003eField fault mirroring to the PLC DO\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0340\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0123\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5294S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.D5294S\/id-2492068\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927571804542,"sku":null,"price":639.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0387_R00_e28ff890-36d2-41ad-bea1-dba5d41620d0.jpg?v=1771102755"},{"product_id":"d5295s","title":"D5295S","description":"\u003cp\u003eSIL3 Relay Out Module for 5 A NE\/ND Loads with LFD\u003c\/p\u003e\n\n\u003cp\u003eThe D5295 is a relay module suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input and output contacts. It makes available 2+2 NC relay contacts connected in parallel and then in series to avoid spurious trip and to increase process availability. High process availability SIL 3 Safety Function for both Normally Energized (NE) and Normally De-energized (ND) \/ F\u0026amp;G loads is available. Load can be isolated from supply on both polarities. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering. Line and load short\/open circuit detection and load voltage monitoring are provided, both when the load is off and when the load is on. The fault in the field is directly mirrored to the PLC DO and it is also reported by opening the fault output. Diagnostic parameters are programmable and can also be monitored\/configured through Modbus.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3 for NE\/ND loads with ND\/NE driver\u003c\/li\u003e\n\u003cli\u003eSIL 2 \/ SC 3 for FAULT OUTPUTS\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2\u003c\/li\u003e\n\u003cli\u003eUp to 5 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eHigh process availability to avoid spurious trips\u003c\/li\u003e\n\u003cli\u003eModbus RTU RS-485 for monitor \u0026amp; configuration\u003c\/li\u003e\n\u003cli\u003eService contact available\u003c\/li\u003e\n\u003cli\u003eInput\/Output\/Supply isolation\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Load short\/open circuit detection\u003c\/li\u003e\n\u003cli\u003eLoad voltage monitoring\u003c\/li\u003e\n\u003cli\u003eEarth leakage monitoring\u003c\/li\u003e\n\u003cli\u003eInternal coil integrity monitoring\u003c\/li\u003e\n\u003cli\u003eField fault mirroring to the PLC DO\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0423\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0222\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D5295S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927573246334,"sku":null,"price":639.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0388_R00_34661840-05b4-4c25-ae5f-c265f972732e.jpg?v=1771102762"},{"product_id":"x1-nis-rloem-01-s","title":"X1-NIS-RLO\/EM-01-S","description":"\u003cp\u003eThe X1-NIS-RLO\/EM-01 electro-magnetic relay module is suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input coils and output contacts, making available a safety NO contact for Normally Energized (NE) loads. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering, while offering an acceptable resistance to the DO Card. To ease maintenance operations, field devices can be disconnected through a two-position insertion\/extraction mechanism. This product requires a dedicated Termination Board.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2 \/ Division 2\u003c\/li\u003e\n\u003cli\u003eLoop disconnection to ease maintenance operations\u003c\/li\u003e\n\u003cli\u003eMechanical polarization key to prevent destructive mismatches\u003c\/li\u003e\n\u003cli\u003eUp to 2 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eThree port isolation, Input\/Output\/Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS1968\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0622%0Ahttps:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0762\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-01-S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.X1-NIS-RLO%252FEM-01-S\/id-2344543\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927611650430,"sku":null,"price":135.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1308_R00_5a59b833-ce75-469b-a757-809875aded1f.jpg?v=1771104492"},{"product_id":"x1-nis-rloem-02-s","title":"X1-NIS-RLO\/EM-02-S","description":"\u003cp\u003eThe X1-NIS-RLO\/EM-02 electro-magnetic relay module is suitable for switching safety related circuits, up to SIL 2 level, for high risk industries. It provides isolation between input coils and output contacts, making available a safety NO contact for Normally Energized (NE) loads. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering, while offering an acceptable resistance to the DO Card. To ease maintenance operations, field devices can be disconnected through a two-position insertion\/extraction mechanism. This product requires a dedicated Termination Board.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 2 \/ SC 3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2 \/ Division 2\u003c\/li\u003e\n\u003cli\u003eLoop disconnection to ease maintenance operations\u003c\/li\u003e\n\u003cli\u003eMechanical polarization key to prevent destructive mismatches\u003c\/li\u003e\n\u003cli\u003eUp to 2 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eTwo port isolation, Input\/Output\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS1969\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0762%0Ahttps:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0623\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-02-S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.X1-NIS-RLO%252FEM-02-S\/id-2343441\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927611683198,"sku":null,"price":88.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1308_R00_f94e676f-8e09-493e-a6d7-15293cb6c0d0.jpg?v=1771104500"},{"product_id":"x1-nis-rloem-03-s","title":"X1-NIS-RLO\/EM-03-S","description":"\u003cp\u003eThe X1-NIS-RLO\/EM-03 electro-magnetic relay module is suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input coils and output contacts, making available a safety NO contact for Normally De-energized (ND) or Fire \u0026amp; Gas (F\u0026amp;G) loads. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering, while offering an acceptable resistance to the DO Card. To ease maintenance operations, field devices can be disconnected through a two-position insertion\/extraction mechanism. This product requires a dedicated Termination Board.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2 \/ Division 2\u003c\/li\u003e\n\u003cli\u003eLoop disconnection to ease maintenance operations\u003c\/li\u003e\n\u003cli\u003eMechanical polarization key to prevent destructive mismatches\u003c\/li\u003e\n\u003cli\u003eUp to 2 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eThree port isolation, Input\/Output\/Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS1970\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0762%0Ahttps:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0624\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-03-S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.X1-NIS-RLO%252FEM-03-S\/id-2345138\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927611748734,"sku":null,"price":151.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1308_R00_88ad06c9-25d8-4263-a969-8956d28d96b7.jpg?v=1771104507"},{"product_id":"x1-nis-rloem-04-s","title":"X1-NIS-RLO\/EM-04-S","description":"\u003cp\u003eThe X1-NIS-RLO\/EM-04 electro-magnetic relay module is suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input coils and output contacts, making available a safety NO contact for Normally Energized (NE) loads. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering, while offering an acceptable resistance to the DO Card. Line and load short\/open circuit detection with programmable limits and load voltage monitoring are provided, both when the load is off and when the load is on. The fault in the field is directly mirrored to the PLC DO by artificially increasing the input impedance without commuting the relay contacts, and it is also reported to the cumulative fault. To ease maintenance operations, field devices can be disconnected through a two-position insertion\/extraction mechanism. This product requires a dedicated Termination Board.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2 \/ Division 2\u003c\/li\u003e\n\u003cli\u003eLoop disconnection to ease maintenance operations\u003c\/li\u003e\n\u003cli\u003eMechanical polarization key to prevent destructive mismatches\u003c\/li\u003e\n\u003cli\u003eUp to 2 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Load short\/open circuit detection (programmable thresholds)\u003c\/li\u003e\n\u003cli\u003eLoad voltage monitoring\u003c\/li\u003e\n\u003cli\u003eField fault mirroring to the DCS\/PLC DO Card\u003c\/li\u003e\n\u003cli\u003eThree port isolation, Input\/Output\/Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS1971\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0621%0Ahttps:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0762\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-04-S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.X1-NIS-RLO%252FEM-04-S\/id-2349474\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927611912574,"sku":null,"price":311.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1308_R00.jpg?v=1771104515"},{"product_id":"x1-nis-rloem-05-s","title":"X1-NIS-RLO\/EM-05-S","description":"\u003cp\u003eThe X1-NIS-RLO\/EM-05 electro-magnetic relay module is suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input coils and output contacts, making available a safety NO contact for Normally De-energized (ND) or Fire \u0026amp; Gas (F\u0026amp;G) loads. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering, while offering an acceptable resistance to the DO Card. Line and load short\/open circuit detection with programmable limits and load voltage monitoring are provided, both when the load is off and when the load is on. The fault in the field is directly mirrored to the PLC DO by artificially increasing the input impedance without commuting the relay contacts, and it is also reported to the cumulative fault. To ease maintenance operations, field devices can be disconnected through a two-position insertion\/extraction mechanism. This product requires a dedicated Termination Board.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2 \/ Division 2\u003c\/li\u003e\n\u003cli\u003eLoop disconnection to ease maintenance operations\u003c\/li\u003e\n\u003cli\u003eMechanical polarization key to prevent destructive mismatches\u003c\/li\u003e\n\u003cli\u003eUp to 2 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eLine \u0026amp; Load short\/open circuit detection (programmable thresholds)\u003c\/li\u003e\n\u003cli\u003eLoad voltage monitoring\u003c\/li\u003e\n\u003cli\u003eField fault mirroring to the DCS\/PLC DO Card\u003c\/li\u003e\n\u003cli\u003eThree port isolation, Input\/Output\/Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS1972\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0620%0Ahttps:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0762\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/EM-05-S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.X1-NIS-RLO%252FEM-05-S\/id-2350054\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927611978110,"sku":null,"price":311.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1308_R00_a75d4032-cb8e-4274-83b7-756625e00ad5.jpg?v=1771104523"},{"product_id":"x1-nis-rloss-01-s","title":"X1-NIS-RLO\/SS-01-S","description":"\u003cp\u003eThe X1-NIS-RLO\/SS-01 solid-state relay module is suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input coils and output contacts, making available a safety NO contact for Normally Energized (NE) loads. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering, while offering an acceptable resistance to the DO Card. To ease maintenance operations, field devices can be disconnected through a two-position insertion\/extraction mechanism. This product requires a dedicated Termination Board.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2 \/ Division 2\u003c\/li\u003e\n\u003cli\u003eLoop disconnection to ease maintenance operations\u003c\/li\u003e\n\u003cli\u003eMechanical polarization key to prevent destructive mismatches\u003c\/li\u003e\n\u003cli\u003eUp to 2 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eLoad disconnection on both supply lines available\u003c\/li\u003e\n\u003cli\u003eThree port isolation, Input\/Output\/Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS1588\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0762%0Ahttps:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0625\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/SS-01-S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.X1-NIS-RLO%252FSS-01-S\/id-2415847\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927612010878,"sku":null,"price":135.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1309_R00_0c89b3f9-9b9f-4112-9dd7-9645503fa03b.jpg?v=1771104530"},{"product_id":"x1-nis-rloss-02-s","title":"X1-NIS-RLO\/SS-02-S","description":"\u003cp\u003eThe X1-NIS-RLO\/SS-02 solid-state relay module is suitable for switching safety related circuits, up to SIL 2 level, for high risk industries. It provides isolation between input coils and output contacts, making available a safety NO contact for Normally Energized (NE) loads. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering, while offering an acceptable resistance to the DO Card. To ease maintenance operations, field devices can be disconnected through a two-position insertion\/extraction mechanism. This product requires a dedicated Termination Board.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 2 \/ SC 3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2 \/ Division 2\u003c\/li\u003e\n\u003cli\u003eLoop disconnection to ease maintenance operations\u003c\/li\u003e\n\u003cli\u003eMechanical polarization key to prevent destructive mismatches\u003c\/li\u003e\n\u003cli\u003eUp to 2 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eThree port isolation, Input\/Output\/Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS1589\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0762%0Ahttps:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0626\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/SS-02-S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.X1-NIS-RLO%252FSS-02-S\/id-2415853\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927612043646,"sku":null,"price":88.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1309_R00_4c44d2c4-a74f-42bd-aba7-5f55ff9c9716.jpg?v=1771104538"},{"product_id":"x1-nis-rloss-03-s","title":"X1-NIS-RLO\/SS-03-S","description":"\u003cp\u003eThe X1-NIS-RLO\/SS-03 solid-state relay module is suitable for switching safety related circuits, up to SIL 3 level, for high risk industries. It provides isolation between input coils and output contacts, making available a safety NO contact for Normally De-energized (ND) or Fire \u0026amp; Gas (F\u0026amp;G) loads. A wide compatibility towards different DCS\/PLC is guaranteed: driving pulse testing is permitted by a dedicated internal circuit, which prevents contact and LED flickering, while offering an acceptable resistance to the DO Card. To ease maintenance operations, field devices can be disconnected through a two-position insertion\/extraction mechanism. This product requires a dedicated Termination Board.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eSIL 3 \/ SC 3\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 2 \/ Division 2\u003c\/li\u003e\n\u003cli\u003eLoop disconnection to ease maintenance operations\u003c\/li\u003e\n\u003cli\u003eMechanical polarization key to prevent destructive mismatches\u003c\/li\u003e\n\u003cli\u003eUp to 2 A functional \/ 6 A inrush current\u003c\/li\u003e\n\u003cli\u003eCompatible with DCS\/PLC pulse testing\u003c\/li\u003e\n\u003cli\u003eThree port isolation, Input\/Output\/Supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS1590\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0762%0Ahttps:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=ISM\u0026amp;ID=ISM0627\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eInstruction manual\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=X1-NIS-RLO\/SS-03-S\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/dataportal.eplan.com\/part-details\/G.M.%20International\/GMI.X1-NIS-RLO%252FSS-03-S\/id-2415848\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eEPLAN dataset\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927612076414,"sku":null,"price":151.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1309_R00_f62360d5-7670-45e3-8ed8-1e626c647691.jpg?v=1771104545"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/collections\/SAFETY_RELAYS_IMG1125_R00_7ec9105b-a2d3-4024-b8f0-1c7a393394ed.jpg?v=1768782637","url":"https:\/\/sklep.trautomatyka.pl\/collections\/d1000-izolatory-iskrobezpieczne-kopia.oembed","provider":"GM International Polska","version":"1.0","type":"link"}