{"title":"D2000","description":"\u003ctable bgcolor=\"#fff\" style=\"width: 100%; background-color: rgb(255, 255, 255); border-collapse: collapse; border: 1px solid rgb(255, 255, 255); height: 150.312px;\" width=\"100%\"\u003e\n\u003ctbody bgcolor=\"#fff\" style=\"background-color: #fff;\"\u003e\n\u003ctr bgcolor=\"#fff\" style=\"background-color: rgb(255, 255, 255); height: 150.312px;\"\u003e\n\u003ctd bgcolor=\"#fff\" colspan=\"2\" style=\"width: 99.9107%; background-color: rgb(255, 255, 255); border: 1px solid rgb(255, 255, 255); height: 150.312px;\"\u003e\n\u003ch2\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eMultiplexer Systems\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-lg-12\"\u003e\n\u003cp\u003e\u003cstrong\u003eD2000 temperature multiplexer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehas been designed specifically for temperature measurements in hazardous location; taking full advantage of the low power requirements inherent of temperature measurement.\u003c\/p\u003e\n\u003cp\u003eField units do not require separate power supply nor certified enclosure.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv bgcolor=\"#fff\" style=\"background-color: #fff;\" class=\"row\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable bgcolor=\"#fff\" width=\"100%\" style=\"width: 100%; background-color: rgb(255, 255, 255); border-collapse: collapse; border: 1px solid rgb(255, 255, 255);\"\u003e\n\u003ctbody bgcolor=\"#fff\" style=\"background-color: #fff;\"\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 50%; background-color: rgb(255, 255, 255); border: 1px solid rgb(255, 255, 255); vertical-align: top;\"\u003e\n\u003csection class=\"PaddingMobile\" id=\"testo75\"\u003e\n\u003cdiv class=\"content-wrap\"\u003e\n\u003cdiv class=\"container clearfix\"\u003e\n\u003cdiv class=\"row mb-0\"\u003e\n\u003cdiv class=\"col-md-4\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eSTRENGTHS\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReduced foot print, high density, up to 256 channel\u003c\/li\u003e\n\u003cli\u003eLonger distances, up to 4\/5 Km between sensor gateway\u003c\/li\u003e\n\u003cli\u003eHigher reliability, certified -40° to + 60° C\u003c\/li\u003e\n\u003cli\u003eAvoid fault propagation, channel to channel isolation -\u003c\/li\u003e\n\u003cli\u003eResilience to surges: 500 V isolation\u003c\/li\u003e\n\u003cli\u003eFaster reaction time: from 0,4 sec for 64 ch. to 1.6 sec for 256 ch.\u003c\/li\u003e\n\u003cli\u003eFaster data collection: 112 KBaud communication speed\u003c\/li\u003e\n\u003cli\u003eHarsh environment resistance, G3 conformal coating\u003c\/li\u003e\n\u003cli\u003eEasier troubleshooting, status LED indication\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50%; background-color: rgb(255, 255, 255); border: 1px solid rgb(255, 255, 255); vertical-align: top; padding: 10px;\"\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/D2000_web2.png?v=1764792375\" style=\"max-width: 100%; height: auto; display: block;\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#fff\" style=\"background-color: rgb(255, 255, 255);\"\u003e\n\u003ctd bgcolor=\"#fff\" colspan=\"2\" style=\"width: 100%; background-color: rgb(255, 255, 255); border: 1px solid rgb(255, 255, 255); vertical-align: top;\"\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cstrong\u003eCost and installation savings\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\n\u003cspan style=\"color: rgb(0, 170, 255);\"\u003e\u003cstrong\u003e\u003cspan dir=\"auto\"\u003e\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\u003cspan dir=\"auto\" style=\"vertical-align: inherit;\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eMULTIPLEXER ADVATAGES \u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"list-style-type: none;\"\u003e\n\u003cul\u003e\n\u003cli\u003eTransferring multiple variables onto the same 2 wires\u003c\/li\u003e\n\u003cli\u003eData sent through a single, or redundant, communication line to the gateway placed in safe area\u003c\/li\u003e\n\u003cli\u003eCost saving: reduced and simplified wiring, lesser cabinet space and clutter free installation\u003c\/li\u003e\n\u003cli\u003eEliminates the need of PLC - DCS AI cards\u003c\/li\u003e\n\u003cli\u003eInstallation in Zone 1 without the need of external power source or certified enclosures\u003c\/li\u003e\n\u003cli\u003eUp to 256 signals per system; maximum 7.936 ch.\u003c\/li\u003e\n\u003cli\u003e18 Bits resolution and fast communication speed\u003c\/li\u003e\n\u003cli\u003eRedundant communication lines to hazardous area (proprietary protocol)\u003c\/li\u003e\n\u003cli\u003eRedundant communication to PLC\/DCS\/PC via Modbus RTU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr bgcolor=\"#fff\" style=\"background-color: rgb(255, 255, 255);\"\u003e\n\u003ctd bgcolor=\"#fff\" style=\"width: 50%; background-color: rgb(255, 255, 255); border: 1px solid rgb(255, 255, 255); vertical-align: top;\"\u003e\u003c\/td\u003e\n\u003ctd bgcolor=\"#fff\" style=\"width: 50%; background-color: rgb(255, 255, 255); border: 1px solid rgb(255, 255, 255); vertical-align: top;\"\u003e\n\u003ch3\u003e\u003cspan style=\"color: rgb(0, 170, 255);\"\u003eSTRUCTURE\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/d2000-frecce21.png?v=1771010031\" style=\"max-width: 100%; height: auto; display: block;\"\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","products":[{"product_id":"d2010m","title":"D2010M","description":"\u003cp\u003eIntrinsically Safe\u003cbr\u003e\nAnalog-Temperature Multiplexer\u003cbr\u003e\nDIN-Rail Model D2010M\u003c\/p\u003e\n\n\u003cp\u003eD2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area\/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single\/redundant 2 wires data communication\/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area\/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer D2010M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area\/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area\/Hazardous Locations acquisition of low level signals from mV, thermocouples, thermoresistances or mA (via external shunt device like D1090Q four channel shunt resistor) sources. D2010M scans all channels using state of the art solid state isolated relays, and stores all data in a memory buffer, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2010M unit accepts directly up to 16 input channels and, by adding from one to three D2011M units, is expandable to 64 channels in blocks of 16 channels each. Four D2010M units, connected to twelve D2011M Expander units, achieve 256 inputs with a single Modbus Gateway D2050M unit. Redundant communication is obtained by dual data\/supply interface line. Safety parameters mantain compatibility with Gas Group IIC or Gas Group A and B, even in redundant mode. An integrating type, high rejection, high accuracy (18 bits) A\/D converter, provides accurate and stable measurements. All parameters are software configurable by serial commands via D2050M Gateway unit. Functions and serial commands for RS-232 and RS-485 protocols are provided in the instruction manual.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe for installation in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area\/Hazardous Location.\u003c\/li\u003e\n\u003cli\u003eUniversal inputs (mV, TC, RTD) from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.\u003c\/li\u003e\n\u003cli\u003eIsolation of 200 V input to input (mV or TC), 60 V input to input (RTD) and 500 V input to ground, allows grounded sensors.\u003c\/li\u003e\n\u003cli\u003eExpandability up to 256 analog channels per system and 31 systems on a single Modbus serial link for up to 7936 channels.\u003c\/li\u003e\n\u003cli\u003eRedundant field lines for communication\/supply.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy A\/D converter, 18 bits.\u003c\/li\u003e\n\u003cli\u003eHigh density, 16 channels per unit, 256 channels per system.\u003c\/li\u003e\n\u003cli\u003eConfigurable via D2050M Gateway using PC SWC2090 software (free of charge) or user software.\u003c\/li\u003e\n\u003cli\u003eModbus output allows savings on PLC\/DCS I\/O cards cost.\u003c\/li\u003e\n\u003cli\u003eLower cables, installation and maintenance costs.\u003c\/li\u003e\n\u003cli\u003e1 terminal block per input, no external terminal block required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0120\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D2010M\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927546704254,"sku":null,"price":3798.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1170_R00_9067ec9c-b678-45eb-9ae1-dfc5211a5b3a.png?v=1771101936"},{"product_id":"d2011m","title":"D2011M","description":"\u003cp\u003eIntrinsically Safe Analog-Temperature\u003cbr\u003e\nMultiplexer Expander\u003cbr\u003e\nDIN-Rail Model D2011M\u003c\/p\u003e\n\n\u003cp\u003eD2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area\/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single\/redundant 2 wires data communication\/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area\/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer Expander D2011M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area\/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area\/Hazardous Locations acquisition of low level signals from mV, thermocouples, thermoresistances or mA (via external shunt device like D1090Q four channel shunt resistor) sources. D2011M scans all channels using state of the art solid state isolated relays, and stores all data in the D2010M memory buffer connected to it, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2011M unit accepts directly up to 16 input channels. An integrating type, high rejection, high accuracy (18 bits) A\/D converter installed on D2010M unit that control up to three Expander D2011M, provides accurate and stable measurements. All parameters are software configurable by serial commands via D2050M Gateway unit and stored in the D2010M unit connected to the Expander.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe for installation in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area\/Hazardous Location.\u003c\/li\u003e\n\u003cli\u003eUniversal inputs (mV, TC, RTD) from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.\u003c\/li\u003e\n\u003cli\u003eIsolation of 200 V input to input (mV or TC), 60 V input to input (RTD) and 500 V input to ground, allows grounded sensors.\u003c\/li\u003e\n\u003cli\u003eHigh reliability, SMD components.\u003c\/li\u003e\n\u003cli\u003eHigh density, 16 channels per unit.\u003c\/li\u003e\n\u003cli\u003e1 terminal block per input, no external terminal block required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0121\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D2011M\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927546802558,"sku":null,"price":2489.0,"currency_code":"EUR","in_stock":true}]},{"product_id":"d2030m","title":"D2030M","description":"\u003cp\u003eIntrinsically Safe\u003cbr\u003e\nDigital Multiplexer\u003cbr\u003e\nDIN-Rail Model D2030M\u003c\/p\u003e\n\n\u003cp\u003eD2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area\/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single\/redundant 2 wires data communication\/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area\/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer D2030M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area\/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area\/Hazardous Locations acquisition of voltage free contact or EN60947-5-6 proximity detectors. D2030M scans all channels and stores all data in a memory buffer, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2030M unit accepts directly up to 32 input channels. Four D2030M units achieve 128 inputs with a single Modbus Gateway D2050M unit. Redundant communication is obtained by dual data\/supply interface line. Safety parameters mantain compatibility with Gas Group IIC or Gas Group A and B, even in redundant mode. All parameters are software configurable by serial commands via D2050M Gateway unit. Functions and serial commands for RS-232 and RS-485 protocols are provided in the instruction manual.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe for installation in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area\/Hazardous Location.\u003c\/li\u003e\n\u003cli\u003eInputs from voltage free contacts or EN60947-5-6 proximity detectors from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.\u003c\/li\u003e\n\u003cli\u003eExpandability up to 128 digital channels per system and 31 systems on a single Modbus serial link for up to 3968 channels.\u003c\/li\u003e\n\u003cli\u003eRedundant field lines for communication\/supply.\u003c\/li\u003e\n\u003cli\u003eHigh density, 32 channels per unit, 128 channels per system.\u003c\/li\u003e\n\u003cli\u003eConfigurable via D2050M Gateway using PC SWC2090 software (free of charge) or user software.\u003c\/li\u003e\n\u003cli\u003eModbus output allows savings on PLC\/DCS I\/O cards cost.\u003c\/li\u003e\n\u003cli\u003e1 terminal block per input, no external terminal block required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0123\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D2030M\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927546966398,"sku":null,"price":2357.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1171_R00_0d2985d0-105f-49af-88a4-b02a5150189a.png?v=1771101947"},{"product_id":"d2050m","title":"D2050M","description":"\u003cp\u003eIntrinsically Safe\u003cbr\u003e\nDigital Multiplexer\u003cbr\u003e\nDIN-Rail Model D2050M\u003c\/p\u003e\n\n\u003cp\u003eD2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area\/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single\/redundant 2 wires data communication\/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area\/Non Hazardous Locations and connected to a PLC, DCS or PC. Multiplexer D2030M units can be installed in the field, close to input sensors, for data acquisition of signal from Hazardous Area\/Hazardous Locations Zone 0-1-2 or Class I, Class II, Class III, Division 1-2. The units are primarily intended for Hazardous Area\/Hazardous Locations acquisition of voltage free contact or EN60947-5-6 proximity detectors. D2030M scans all channels and stores all data in a memory buffer, where they can be rapidly accessed by the Modbus Gateway D2050M unit. Each D2030M unit accepts directly up to 32 input channels. Four D2030M units achieve 128 inputs with a single Modbus Gateway D2050M unit. Redundant communication is obtained by dual data\/supply interface line. Safety parameters mantain compatibility with Gas Group IIC or Gas Group A and B, even in redundant mode. All parameters are software configurable by serial commands via D2050M Gateway unit. Functions and serial commands for RS-232 and RS-485 protocols are provided in the instruction manual.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Associated Apparatus for installation in Safe Area\/Non Hazardous Locations to supply Multiplexer D2010M, D2011M, D2030M installed in Zone 1, 2 Gas Group IIC, IIB, IIA T4 or Class I, Division 1, 2 Groups A, B, C, D, Temperature Code T4 and Class I, Zone 1, 2 Groups IIC, IIB, IIA, Temperature Code T4 Hazardous Area\/Hazardous Location.\u003c\/li\u003e\n\u003cli\u003eUniversal inputs (mV, TC, RTD, contact or proximity detector) via D2010M, D2011M, D2030M unit from Zone 0, 1, 2 or Class I, II, III, Division 1, 2, Groups A, B, C, D, E, F, G, and Class I, Zone 0, 1, 2 Groups IIC, IIB, IIA Hazardous Location.\u003c\/li\u003e\n\u003cli\u003eExpandability up to 256 analog\/128 digital channels per system and 31 systems on a single Modbus serial link for up to 7936\/3968 channels.\u003c\/li\u003e\n\u003cli\u003eRedundant field lines for communication\/supply.\u003c\/li\u003e\n\u003cli\u003eModbus interface RTU protocol on redundant RS-485.\u003c\/li\u003e\n\u003cli\u003eRS-232 port for system configuration.\u003c\/li\u003e\n\u003cli\u003eConfigurable by SWC2090 software (free of charge) or user software.\u003c\/li\u003e\n\u003cli\u003eModbus output allows savings on PLC\/DCS I\/O cards cost.\u003c\/li\u003e\n\u003cli\u003eRepeat Hazardous Area\/Hazardous Locations input contact or proximity detector in Safe Area\/Non Hazardous Locations via D2052M unit (relay output) or via D2053M unit (transistor output).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0122\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D2050M\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927546999166,"sku":null,"price":2619.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG1172_R00_0cad677e-efa1-4e1a-8776-3b7c1be53f42.png?v=1771101953"},{"product_id":"d2052m","title":"D2052M","description":"\u003cp\u003eRelay Output Repeater\u003cbr\u003e\nDIN-Rail Model D2052M\u003c\/p\u003e\n\n\u003cp\u003eD2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area\/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single\/redundant 2 wires data communication\/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area\/Non Hazardous Locations and connected to a PLC, DCS or PC. The D2052M unit is primarily intended for replication of proximity sensor or voltage free contact status of devices located in Hazardous Area\/Hazardous Locations in the Safe Area\/Non Hazardous Locations. When connected to D2050M unit, it repeats the status of each D2030M digital input multiplexer unit. The unit is driven by the Gateway D2050M via a dedicated bus. Application of this devices allows the reduction in cabling complexity where digital status are to be repeated in discrete form, in addition to the capability of analyzing them via Modbus. The D2052M unit is equipped with 32 relay output SPDT contacts. The repeaters have the same channel capability as the digital field devices, so that every input unit can be repeated on an output unit. The assignment between input (field) and output (Safe Area\/Non Hazardous Locations) devices is managed by the software of the D2050M and corresponding internal settings. The relay output is of the changeover type allowing the use of normally close or normally open contacts.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eOutput Repeater for D2030M Digital Multiplexer.\u003c\/li\u003e\n\u003cli\u003eSPDT Relay Output Signals.\u003c\/li\u003e\n\u003cli\u003eHigh density, 32 channels per unit, 128 channels per system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0124\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D2052M\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927547064702,"sku":null,"price":1179.0,"currency_code":"EUR","in_stock":true}]},{"product_id":"d2053m","title":"D2053M","description":"\u003cp\u003eTransistor Output Repeater\u003cbr\u003e\nDIN-Rail Model D2053M\u003c\/p\u003e\n\n\u003cp\u003eD2000M series Intrinsically Safe Multiplexing System consists of one to four Analog-Temperature Multiplexer units model D2010M, up to twelve Expander units model D2011M, or up to four Digital Multiplexer units model D2030M, mounted in Hazardous Area\/Hazardous Locations Zone 1-2, Gas Group IIC-IIB-IIA T4 or Class I, Division 1-2, Group A, B, C, D T4 and connected via a single\/redundant 2 wires data communication\/supply line to a Modbus Gateway unit model D2050M, mounted in Safe Area\/Non Hazardous Locations and connected to a PLC, DCS or PC. The D2053M unit is primarily intended for replication of proximity sensor or voltage free contact status of devices located in Hazardous Area\/Hazardous Locations in the Safe Area\/Non Hazardous Locations. When connected to D2050M unit, it repeats the status of each D2030M digital input multiplexer unit. The unit is driven by the Gateway D2050M via a dedicated bus. Application of this devices allows the reduction in cabling complexity where digital status are to be repeated in discrete form, in addition to the capability of analyzing them via Modbus. The D2053M unit is equipped with 32 optocoupled transistor output. The repeaters have the same channel capability as the digital field devices, so that every input unit can be repeated on an output unit. The assignment between input (field) and output (Safe Area\/Non Hazardous Locations) devices is managed by the software of the D2050M and corresponding internal settings.\u003c\/p\u003e\n\n\u003cul\u003e\n\u003cli\u003eOutput Repeater for D2030M Digital Multiplexer.\u003c\/li\u003e\n\u003cli\u003eOpto isolated voltage free Transistor Output Signals.\u003c\/li\u003e\n\u003cli\u003eHigh density, 32 channels per unit, 128 channels per system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/gminternational.com\/inc\/inc_getfile.cfm?w=DTS\u0026amp;ID=DTS0125\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDatasheet\u003c\/a\u003e\u003cbr\u003e\n\u003ca href=\"https:\/\/gminternational.com\/?fuseaction=skdprodotti\u0026amp;IDProdotto=D2053M\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eProduct page\u003c\/a\u003e\u003c\/p\u003e","brand":"G.M. International","offers":[{"title":"Default Title","offer_id":56927547097470,"sku":null,"price":956.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/files\/IMG0327_R00_4e3397d2-92a9-40ae-a010-2f792e02c102.jpg?v=1771101963"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0972\/6171\/5838\/collections\/D1000_web2_d7ca5561-6556-411c-b143-d80da32cd4e3.png?v=1768760698","url":"https:\/\/sklep.trautomatyka.pl\/collections\/przekazniki-bezpieczenstwa-kopia.oembed","provider":"GM International Polska","version":"1.0","type":"link"}