Item added to your cart
G.M. International
Use this text to display some key features of the products
Use this text to display some key features of the products
Load Cell/Strain Gauge Bridge
Isolating Repeater DIN-Rail
Model D1063S
The single channel DIN Rail Load Cell/Strain Gauge Bridge Isolating Repeater D1063S acts as a transparent galvanic isolated interface installed between a weighing indicator in Safe Area and a load cell (or group of load cells) in Hazardous Area; it appears at the terminals of the indicator as a single load cell equivalent to the one in the field. Provides a fully floating power supply voltage with remote sensing capability to load cell located in Hazardous Area and repeats, while isolating, the mV signal output to drive a load in Safe Area depending on the host system reference voltage. Up to four 350 Ω load cells, or six 450 Ω load cells, or twelve 1000 Ω load cells can be connected in parallel. Voltage reference (Safe Area side) is DIP switch configurable to select internal or external (host system) supply. In addition a field wiring fault red LED indicates any wire break in the Hazardous Area side.
| Operating Temperature | -20...+60 °C |
| Output Type | Weighing indicator interface |
| Supply Voltage | 24 Vdc |
| Input Range | 350 Ω load cells (max 4) |
| Input Type | Load Cell/Strain Gauge interface |
| Channels | 1 N. |